| Milestone | Planned | Status |
|---|---|---|
| MEP Rough-In Lvl 2 | Apr 4 | At Risk |
| Drywall Complete | Apr 18 | On Track |
| Above-Ceiling Insp. | Apr 22 | On Track |
| Substantial Completion | Jul 14 | Tracking |
| Company | Trade | License | Ins. Expires | Bond | EMR | Score | Status |
|---|
| Sheet | Title | Discipline | Rev | Date | Open RFIs | Status |
|---|---|---|---|---|---|---|
| A-101 | Floor Plan — Level 1 | Architectural | 3 | Mar 1 | — | Current |
| A-102 | Floor Plan — Level 2 | Architectural | 3 | Mar 1 | — | Current |
| S-101 | Foundation Plan | Structural | 3 | Mar 1 | RFI-003 | RFI Open |
| M-101 | Mechanical — Level 1 | Mechanical | 3 | Mar 1 | — | Current |
| E-101 | Electrical — Level 1 | Electrical | 3 | Mar 1 | — | Current |
| FP-101 | Fire Protection — Level 1 | Fire Protection | 2 | Feb 8 | RFI-007 | RFI Open |
| Addendum | Date | Sheets | Status |
|---|---|---|---|
| Addendum 1 | Feb 2 | 3 sheets | Incorporated |
| Addendum 2 | Mar 1 | 5 sheets | Incorporated |
| # | Description | Spec | Sub | Submitted | A/E Due | Disposition |
|---|---|---|---|---|---|---|
| 001-A | Structural Steel Shop Drawings | 05 12 00 | Steel Plus | Feb 14 | Mar 14 | Approved |
| 008-A | HVAC Ductwork Shop Drawings | 23 31 13 | Apex Mech. | Feb 28 | Mar 28 | App. as Noted |
| 012-A | Electrical Panel Schedules | 26 24 16 | Bright Elec. | Mar 10 | Apr 10 | Pending A/E |
| 014-B | Roofing Membrane — Product Data | 07 52 16 | Premier Roof. | Mar 18 | Apr 4 ! | Pending A/E |
| 019-A | Door Hardware Schedule | 08 71 00 | Not assigned | Not submitted | OVERDUE | Overdue |
| 031-A | Fire Alarm Devices & Riser | 28 31 11 | Bright Elec. | Mar 1 | Mar 31 | Revise & Res. |
| RFI # | Subject | Drawing | Ball in Court | Submitted | Days Open | Cost Impact | Status |
|---|---|---|---|---|---|---|---|
| 003 | Beam pocket depth — Grid B/4 | S-201 | Structural EOR | Feb 2 | 49 | TBD | Overdue |
| 007 | Roof drain sizing — FP conflict | FP-101 | MEP EOR | Mar 19 | 4 | None | Open |
| 005 | Window sill flashing — Add.2 conflict | A-501 | — | Feb 20 | — | $4,800 | Closed |
| # | Description | Location | Trade | Priority | Due | Status |
|---|---|---|---|---|---|---|
| P-001 | Missing security screw in strike plate — door 112A | Lvl 1, Rm 112 | Door Hardware | Medium | Mar 28 | Closed |
| P-002 | Door closer not adjusted — door 218B not latching | Lvl 2, Corr. B | Hardware | Medium | Apr 4 | Open |
| P-003 | Missing silencers — door 224A (3 required) | Lvl 2, Rm 224 | Hardware | Low | Apr 4 | Open |
| P-004 | Molex connector not used — field-spliced wire door 108A | Lvl 1, Entry | Low Voltage | High | Mar 29 | In Progress |
| P-005 | LIFE SAFETY — Exit device door 102A not functioning | Lvl 1, Stair 1 | Hardware / FA | Life Safety | TODAY | Escalated |
| Div. | Description | Budget | Committed | Actual | % Cmplt | Variance |
|---|---|---|---|---|---|---|
| 03 | Concrete | $342K | $342K | $342K | 100% | $0 |
| 05 | Structural Steel | $620K | $618K | $618K | 100% | +$1.5K |
| 07 | Thermal & Moisture | $210K | $210K | $165K | 79% | $0 |
| 23 | HVAC | $580K | $580K | $261K | 45% | -$18.2K |
| 26 | Electrical | $490K | $537K | $196K | 40% | -$47.2K |
| Activity | Planned Start | Planned Finish | Forecast | Status |
|---|---|---|---|---|
| Notice to Proceed | Oct 1, 2025 | Oct 1, 2025 | Oct 1, 2025 | Complete |
| Structural Steel Erection | Nov 15, 2025 | Jan 10, 2026 | Jan 10, 2026 | Complete |
| Building Enclosed / Dry-In | Jan 25, 2026 | Feb 28, 2026 | Mar 3, 2026 | 3 days late |
| MEP Rough-In Level 2 | Mar 10, 2026 | Apr 4, 2026 | Apr 7 (fcst) | Critical — At Risk |
| Above-Ceiling Inspection | Apr 10, 2026 | Apr 22, 2026 | Apr 25 (fcst) | Tracking late |
| Substantial Completion | Jul 14, 2026 | Jul 14, 2026 | Jul 17 (fcst) | 3 day risk |
| DFOW # | Feature of Work | Spec | Subcontractor | Phase | Status | Score | |
|---|---|---|---|---|---|---|---|
| DFOW-001 | Structural Concrete — Slab on Grade | 03 30 00 | GC Self-Perform | Follow-Up | Complete | 96 | |
| DFOW-002 | Structural Steel Erection | 05 12 00 | Steel Plus Inc. | Follow-Up | Complete | 97 | |
| DFOW-003 | MEP Rough-In — Level 1 | 23 31 13 / 26 05 00 | Apex / Bright Elec. | Follow-Up | Complete | 84 | |
| DFOW-004 | MEP Rough-In — Level 2 ← ACTIVE | 23 31 13 / 26 05 00 | Apex / Bright Elec. | Initial Phase | In Progress | Active | |
| DFOW-005 | Drywall Framing & Hang | 09 21 16 | GC Self-Perform | Preparatory | Not Started | — | |
| DFOW-006 | Door Frame & Hardware Install | 08 11 13 / 08 71 00 | GC / Hardware Sub | Not Started | Upcoming | — | |
| DFOW-007 | Roofing — TPO Membrane System | 07 52 16 | Premier Roofing | Not Started | Upcoming | — |
| Type | DFOW | Status |
|---|---|---|
| Concrete — Cylinder Breaks | DFOW-001 | Complete |
| Steel — Weld Visual | DFOW-002 | Complete |
| Steel — Bolt Torque | DFOW-002 | Complete |
| Fireproofing — Thickness | DFOW-002 | Sched Apr 8 |
| DEF # | Description | Location | Trade | Severity | Logged | Due | Status |
|---|---|---|---|---|---|---|---|
| DEF-041 | Ductwork support spacing exceeds 8 ft — Rooms 218-219 | Lvl 2 | Apex Mech. | Major | Mar 21 | Mar 24 | Open |
| DEF-042 | Conduit strap missing within 3 ft of J-box — Rm 220 | Lvl 2 | Bright Elec. | Major | Mar 23 | Mar 25 | Open |
| DEF-043 | LIFE SAFETY — Fire barrier sleeve missing, Corridor B | Lvl 2 | Bright Elec. | Life Safety | Mar 23 | Mar 24 | Escalated |
| DEF # | DFOW | Description | Trade | Severity | Logged | Due | Days | Status | |
|---|---|---|---|---|---|---|---|---|---|
| DEF-038 | DFOW-003 | Duct support at 10 ft — exceeds SMACNA 8 ft max | Apex Mech. | Major | Mar 12 | Mar 15 | — | Closed | |
| DEF-039 | DFOW-003 | Conduit strap missing within 3 ft of J-box Rm 114 | Bright Elec. | Major | Mar 14 | Mar 17 | — | Closed | |
| DEF-041 | DFOW-004 | Ductwork support spacing exceeds 8 ft — Rooms 218-219 | Apex Mech. | Major | Mar 21 | Mar 24! | 2 | Open | |
| DEF-042 | DFOW-004 | Conduit strap missing within 3 ft of J-box Rm 220 | Bright Elec. | Major | Mar 23 | Mar 25 | 0 | Open | |
| DEF-043 | DFOW-004 | LIFE SAFETY — Fire barrier sleeve missing, Corridor B | Bright Elec. | Life Safety | Mar 23 | Mar 24! | 0 | Escalated |
| Division | Description | Unit | Qty | Unit Cost (RS Means) | CCI Adj. | Total | % of Project |
|---|---|---|---|---|---|---|---|
| TOTAL DIRECT COST | |||||||
| General Conditions (8%) | |||||||
| Overhead & Profit (12%) | |||||||
| TOTAL BID PRICE | |||||||
| Trade | RS Means Budget | Sub Bid #1 | Sub Bid #2 | Variance | Rec. |
|---|---|---|---|---|---|
| HVAC | $580,000 | $568,000 | $612,000 | -2% | Use #1 |
| Electrical | $490,000 | $537,000 | $498,000 | +2% | Negotiate |
| Roofing | $148,000 | $161,000 | $144,000 | -3% | Use #2 |
| CO # | Description | Initiated By | Reason | Amount | Days | Submitted | Status |
|---|---|---|---|---|---|---|---|
| CO-001 | Added electrical outlets — Rooms 208-212 | Owner | Owner Directed | +$28,400 | 0 | Jan 15 | Approved |
| CO-002 | Window sill flashing redesign — RFI-005 | GC | Design Error | +$4,800 | 3 | Mar 2 | Approved |
| CO-003 | Electrical scope additions — BAS integration panel | Owner | Owner Directed | +$47,200 | 0 | Mar 15 | Approved |
| PCO-004 | Unforeseen rock excavation — NE corner site work | GC | Differing Site Conditions | +$67,500 | 5 | Mar 20 | Under Review |
| PCO-005 | Additional fire blocking — AHJ field directive | GC | Code Compliance | +$27,000 | 0 | Mar 22 | Submitted |
| Item | Description | Scheduled Value | Prev. Billed | This Period | Stored Matl. | Total to Date | % Cmplt | Balance | Retainage |
|---|---|---|---|---|---|---|---|---|---|
| 1 | General Conditions | $201,000 | $160,800 | $16,083 | $0 | $176,883 | 88% | $24,117 | $8,844 |
| 3 | Concrete (Div 03) | $342,000 | $342,000 | $0 | $0 | $342,000 | 100% | $0 | $17,100 |
| 4 | Structural Steel (Div 05) | $620,000 | $620,000 | $0 | $0 | $620,000 | 100% | $0 | $31,000 |
| 7 | HVAC (Div 23) | $580,000 | $261,000 | $87,000 | $29,000 | $377,000 | 65% | $203,000 | $18,850 |
| 8 | Electrical (Div 26) | $537,200 | $196,000 | $107,897 | $0 | $303,897 | 57% | $233,303 | $15,195 |
| TOTALS | $3,669,200 | $1,997,000 | $312,480 | $47,000 | $2,357,480 | 64% | $1,311,720 | $117,874 | |
| Article | Provision | Risk | Standard Language | Contract Deviation | Recommended Action |
|---|---|---|---|---|---|
| Art. 15.1.2 | Notice of Claims | HIGH | 21 days from event | Contract reduced to 5 days | Calendar-flag every RFI, change event, and delay occurrence. Send written notice within 3 days to be safe. |
| Art. 5 / A401 | Subcontract Not Executed | HIGH | Subcontracts executed before work begins | ABC Mechanical working without signed A401 | Execute A401 immediately or issue stop-work notice today. |
| Art. 3.18 | Indemnification Scope | HIGH | Limited to Contractor negligence | Broad form — includes partial owner negligence | Verify enforceability under NC anti-indemnity statute (NCGS 22B-1). Consult legal counsel. |
| Art. 14.1.3 | Contractor Termination Cure | MEDIUM | 7-day cure period | Modified to 3 days | Keep daily logs impeccably current. Any owner-identified issue must be addressed within 24 hours. |
| Art. 8.3 | Delay Damages | MEDIUM | Time extension for excusable delays | No-damage-for-delay clause added | Document ALL owner-caused delays in daily logs and formal delay notices. Build the record now. |
| Art. 9.7 | Late Payment Interest | LOW | Legal rate from date due | Standard AIA language — no deviation | No action required. Favorable provision intact. |
| Notice Type | AIA Article | Trigger Event | Notice Deadline | Status | Days Left |
|---|---|---|---|---|---|
| Claim — Differing Site Conditions | Art. 15.1.2 | Rock encountered NE corner Mar 20 | Mar 25, 2026 | OVERDUE — Verify sent | -2 |
| Pay App Certification | Art. 9.4.1 | App. 7 submitted Mar 23 | Apr 2, 2026 | Pending — A/E action | 6 |
| Sub | Trade | Contract Value | Retainage | Insurance | A401 Status | |
|---|---|---|---|---|---|---|
| Apex Mechanical LLC | HVAC / Plumbing | $778,000 | 5% | Current | Executed Jan 8 | |
| Bright Electric Co. | Electrical | $537,200 | 5% | Current | Executed Jan 12 | |
| ABC Mechanical | HVAC (Supplem.) | $198,000 | 5% | Exp. Apr 1 | NOT EXECUTED | |
| Steel Plus Inc. | Structural Steel | $620,000 | 5% | Current | Executed Oct 20 | |
| Premier Roofing | Roofing | $161,000 | 5% | Current | Executed Feb 1 |
| Document | Form | From | Status |
|---|---|---|---|
| Certificate of Substantial Completion | G704 | Architect | Not Yet — Jul 14 |
| Contractor's Affidavit — Payment of Debts | G706 | GC | Not Yet |
| Contractor's Affidavit — Release of Liens | G706A | GC | Not Yet |
| Consent of Surety to Final Payment | G707 | Surety | Not Yet |
| Punch List — All Items Resolved | — | GC / Owner | In Progress |
| Final Lien Waivers — All Subcontractors | — | All Subs | Through App. 6 |
| O&M Manuals — All Systems | — | GC / Subs | Collecting |
| As-Built Drawings | — | GC | In Progress |
| Certificate of Occupancy | — | AHJ | Not Yet |
| Date | Employee | Description | Days Away | Recordable |
|---|---|---|---|---|
| Feb 4 | J. Hernandez | Sprained ankle — uneven terrain at site entrance | 2 | Yes |
| No recordable incidents since February 4 (47 days) | ||||